• Compact design for space-saving, fast installation
• External unit with compressor with rotational speed control to adjust heating output
• Operation with refrigerant R410A
• Internal unit consisting of:
- Drinking water tank
- Buffer tank
- Heat pump manager
- Tank loading pump
- Heating circuit pump
- Safety valve
- 2/3 way switchover valve
- Additional electric heater
Model |
WPL |
17 ACS classic compact plus Set 1.1 |
EEC space heating low temperature |
A+++ to G |
A+++ |
EEC space heating average temperature |
A+++ to G |
A++ |
Heating capacity/COP according to EN 14511 at: |
|
|
- at A2/W35 nominal output |
[kW/-] |
5.73 / 3.97 |
- at A7/W35 nominal output |
[kW/-] |
4.86 / 4.76 |
for A-7/W35 nominal line |
[kW/-] |
7.80 / 2.92 |
Cooling capacity according to En14511 at: |
|
|
- for A2/W35 nominal line |
[kW/-] |
3.97
|
- for A7/W35 Nominal line |
[kW/-] |
4.76
|
- for A-7/W3 Nominal line |
[kW/-] |
2.92
|
Sound power level |
[dBA] |
57 |
Hot water/buffer tank content |
[l] |
178 / 80 |
External unit dimensions (H x W x D) |
[mm] |
812 x 1152 x 524 |
Internal unit dimensions (H x W x D) |
[mm] |
1910 x 605 x 917 |
Weight of external unit |
[kg] |
91 |
Weight of internal unit |
[kg] |
134 |
Ref. no. |
|
204264 |