Kiss HE fresh water station with electronic pump, for low-temperature use e.g. heat pumps
XXX.XX
€/unit
Description • For hygienic hot water preparation using the instantaneous water heater principle with buffer tanks • Ready to plug in (earthed plug), compact insulated unit with high-efficiency pump • Thermally long plate heat exchanger for ideal heat transfer • Automatic pump speed control with no additional control thanks to integrated sensor in buffer return • Simple cascading for higher output capacities • Shut-off valves in buffer circuit supplied Technical data: • Plate exchanger material: Stainless steel 1.4401 • Insulation material: EPP • Max. operating temperature: 90°C • Max. operating pressure on drinking water side: 6 bar • Operating voltage: 230V/AC No flow temperature control • For use in heat pump systems • Plate exchanger, copper-soldered • Circulation pump: UPM2 15-75 • Connection size: DN25 (1”) ET • Dimensions (H x W x D) with insulation: 580 x 280 x 200 mm *Performance: buffer intake 60°C, cold water 10°C, hot water 45°C See catalogue
|
Products |