• FHA monobloc + hot water tank and buffer tank
- Complete solution for detached and two-family homes (new construction)
• 50 litre row buffer tank incl. overflow valve
• 280 litre hot water tank with smooth pipe heat exchanger (3.0 m²)
• Heating and cooling operation
• 6 kW electric heating element
• Modular design for easy insertion
• BM-2 operating module, integrated 24 litre expansion tank and connection set
External unit:
- Environmentally friendly refrigerant R 32 for flow temperatures up to max. 60-65 °C in pure heat pump operation
• Robust metal housing with optimal protection against environmental impact
- Compact design, even in the large power range with only one fan
Indoor unit:
- Heat meter, 3-way switching valve, water pressure sensor and safety valve already integrated
• Slot for LAN / WLAN LinkHome interface
• Certified to EHPA and HP Keymark
- Mains-ready through SG Ready
Type |
FHA-300-R50 |
05/06 |
06/07 |
08/10 |
11/14 |
EEC space heating low temperature |
A+++ to D |
A+++ |
A+++ |
A+++ |
A+++ |
EEC space heating average temperature |
A+++ to D |
A++ |
A++ |
A++ |
A++ |
EEK hot water tank |
A+ to G |
B |
B |
B |
B |
EEK buffer tank |
A+ to F |
A |
A |
A |
A |
Heating output/COP according to EN 14511 |
|
|
|
|
|
- at A2/W35 nominal output |
[kW/-] |
2.9 / 3.54 |
2.98 / 3.51 |
4.93 / 4.33 |
6.76 / 3.54 |
- at A7/W35 nominal output |
[kW/-] |
2.88 / 4.70 |
3.82 / 5.21 |
3.60 / 4.87 |
6.84 / 5.10 |
- at A-7/W35 nominal output |
[kW/-] |
4.97 / 3.06 |
5.49 / 2.76 |
7.57 / 2.89 |
11.77 / 2.57 |
Cooling output / EER according to EN14511 |
|
|
|
|
|
- at A35/W18 nominal output |
[kW/-] |
|
5.2 / 4.9 |
6.8 / 5.0 |
9.3 / 4.3 |
- at A35/W7 nominal output |
[kW/-] |
|
3.9 / 3.2 |
5.1 / 3.3 |
7.8 / 2.9 |
Hot water/buffer tank content |
[l] |
280 / 49 |
280 / 49 |
280 / 49 |
280 / 49 |
Dimensions of outside unit (W x H x D) |
[mm] |
1295 x 718 x 429 |
1295 x 718 x 429 |
1385 x 865 x 526 |
1385 x 865 x 526 |
Dimensions indoor unit (W x H x D) |
[mm] |
600 x 1829 x 999 |
600 x 1829 x 999 |
600 x 1829 x 999 |
600 x 1829 x 999 |
Hot water/buffer tank weight |
[kg] |
145 / 21 |
145 / 21 |
145 / 21 |
145 / 21 |
Weight outer unit/inner unit |
[kg] |
79 / 27 |
79 / 27 |
98 / 27 |
137 / 27 |
Ref. no. |
|
9148115 |
9148145 |
9148175 |
9148245 |