Gross freshwater station max. 96 l/min.Order no.: 97 024 92
XXX.XX
€/unit
currently not in stock Description For hygienic hot water preparation using the instantaneous water heater principle with buffer tanks • High flow rate, also for low buffer flow temperatures • Limescale protection by way of thermal limitation of the buffer inlet temperature • Low buffer return temperatures, also in partial-load operation • Simple construction, flat-sealing connections • Easy assembly and commissioning • NO electronic adjustment control • Fully pre-assembled and ready to plug in The function: The heat exchanger (A) consists of two series-connected chambers (yellow line symbolises the separation). The flow switch (B) activates the buffer pump (C). The hot buffer water is conducted into the first chamber (red line) via the thermal valve (D). During tapping, the buffer water cooled in the first chamber is added via the thermo valve (orange line) to achieve the pre-set buffer maximum temperature. During tapping, only the volume of water required to maintain the pre-set mixing temperature is extracted - similar to an injection-type system. The “volume of injection water” is between almost zero and 100 percent depending on the tap capacity and buffer temperature. The “injection volume” extracted during operation flows through the second half of the heat exchanger (blue line) via the connection between first and second chamber (E) and there it is cooled further by the inflowing cold water. • Circulation: The circulation unit is fixed on the station and built-in so it is ready to plug for the control mechanism (in the Z design with circulation). Only the circulation pump must be put in on-site. Technical data: • Connection: External thread • Plate heat exchanger material: Copper-soldered stainless steel 1.4401 • Insulation material: EPP • Heating/plumbing max. operating pressure: 3/6 bar • Max. operating temperature: 90°C • Circulation pump size 62/76: UPM2 25-75 • Circulation pump size 96: UPM2 Geo 25-85 • Operating voltage: 230 V/AC, 50-60 Hz See catalogue
To product family Questions regarding itemPlease login beforehand Add to a listPlease login beforehand |
Type: | Large 96 |
Socket: | 96 |
capacity [kW]: | 233 |
Connection cable length [mm]: | 1 |
Min. operating temperature [°C]: | 55 |
Design: | Electronic |
Max. Operating temperature [°C]: | 90 |
Depth [mm]: | 280 |
Max. Flow rate [l/min]: | 96 |
Connection: | External thread |
Operating voltage [V]: | 230 |
Products |