mut
- The zone valves are installed in closed circuits in heating systems. Manual operation, can be locked in intermediate position.
Technical data: - Power consumption: 6 W
- Protection type: IP22
- The zone valves are installed in closed circuits in heating systems. Manual operation, can be locked in intermediate position.
Technical data: - Power consumption: 6 W
- Protection type: IP22
- The zone valves are installed in closed circuits in Heating and solar systems.
With manual operation, lockable in centre position - With integrated limit switch
Technical data: - Power consumption: 6W
- A system with a solid fuel boiler and a buffer tank are prerequisites for use
- For return flow boost
- Thermostat insert can be rotated from the outside
Technical data:
- The zone valves are installed in closed circuits in heating systems. Manual operation, can be locked in intermediate position.
Technical data: - Power consumption: 6 W
- Protection type: IP22
- Pre-assembled with magnetite and dirt separator and automatic vent
- Exchange chamber made of round pipe
- Connection for immersion sensor DN 15 (1/2”)
- Suitable for installation in closed heating circuits and water lines. Can be used as changeover or mixer valve.
- Very quiet changeover with no water hammer
- Actuator can be exchanged without draining the system
- The zone valves are installed in closed circuits in Heating and solar systems.
With manual operation, lockable in centre position - With integrated limit switch
Technical data: - Power consumption: 6W
- The zone valves are installed in closed circuits in Heating and solar systems.
With manual operation, lockable in centre position - With integrated limit switch
Technical data: - Power consumption: 6W
- Angle of rotation: max. 90°
- Medium temperature: 5°C to 110°C
- Material, mixer: Brass
- Heating circuit outflows; adjacent inflow and return
- Separate heating circuit outflow on the side
- Integrated hydraulic switch
- Suitable for MUT Changeover valves Series VMR
- Power consumption: 4 W
- Protection class: IP40
- Suitable for 3-way and 4-way mixers up to DN40 from series 3000 and VMX.
- Can be manually adjusted by pressing and turning the rotary knob
- compact construction
- 1-pin (with relay), with 1x continuous phase and 1x control phase
- Suitable for MUT Changeover valves Series VMR
- Power consumption: 4 W
- - For use in heating, cooling and drinking water systems
- Particularly suitable for systems with larger flow rates, e.g. heat pumps
- Quick and easy disassembly of the actuator
- With built-in relay, SPST control 1x continuous phase and 1x control phase
- Auxiliary microswitch integrated as limit switch
- Scope of delivery:
- Ball valve with actuator
- Molex cable Minifit JR6
Technical data
- Material ball valve: Brass CW617N
- Operating temperature range: 2 to 90 °C
- Operating pressure max.: 10 bar
- Max. differential pressure: 6 bar
- Operating voltage: 230 V/AC
- Protection class: IP 40
- Power consumption max.: 7 W
- Length of connection cable: 1.0 m
- Operating media: Water, glycol (max. 50%) - Actuator operating time: 6 s / 90°
- Incl. screw connection
- - For use in heating and drinking water systems
- Quick and easy disassembly of the actuator
- With built-in relay, SPST control 1x continuous phase and 1x control phase
- Auxiliary microswitch integrated as limit switch
- Scope of delivery:
- Ball valve with actuator
- Molex cable Minifit JR6
- Screw connection
Technical data
- Material ball valve: Brass CW617N
- Operating temperature range: 2 to 90 °C
- Operating pressure max.: 10 bar
- Max. differential pressure: 2.5 bar
- Operating voltage: 230 V/AC
- Protection class: IP 40
- Power consumption max.: 7 W
- Connection cable length: 1.0 m
- Operating media: Water, glycol (max. 50%) - Actuator operating time: 6 s / 90°
- The actuator series AS is suitable for installation on control valve series MK.
Technical data: - Positioning force: 250 N
- Lift: 15 mm
- Length: 1 m
- Technical data:
- Max. operating pressure: 10 bar
- Max. dynamic pressure: 5 bar
- The control valves of the MK series can be used as deflector, mixer and shut-off valves in heating, air-conditioning and ventilation systems and in systems for generating warm water.
Technical data: - Operating pressure: 10 bar
- Media temp.: 5–110 °C
- The control valves of the MK series can be used as deflector, mixer and shut-off valves in heating, air-conditioning and ventilation systems and in systems for generating warm water.
Technical data: - Operating pressure: 10 bar
- Media temp.: 5–110 °C
- For use in heating and drinking water systems- Quick and easy disassembly of the actuator- With built-in relay, SPST control 1x continuous phase and 1x control phase- Auxiliary microswitch integrated as limit switch- Scope of delivery:- Ball valve with actuator- Molex cable Minifit JR6- Screw conn ...
- Use:
Suitable for installation in boiler assemblies of central heating systems.
The mixers are suitable for left or right installation.
Technical data: - Size: DN25 (1")
- Angle of rotation: max. 90°
- For use in heating and drinking water systems- Quick and easy disassembly of the actuator- With built-in relay, SPST control 1x continuous phase and 1x control phase- Auxiliary microswitch integrated as limit switch- Scope of delivery:- Ball valve with actuator- Molex cable Minifit JR6- Screw conn ...