orkli
- No limit switch
For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- No limit switch
For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- No limit switch
For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- Consisting of 6x 3-way zone valve
- Currentless DOWN to B closed
- Without limit switch
- 3-way valve with limit switch
For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- Can be used universally with all Honeywell ignition burners and for ignition burners from most other manufacturers
- Plastic-welded
- incl. adapter fitting pieces and assembly manual
- No limit switch
For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
Normally closed (2-way), normally open AB-B (3-way).
They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
Technical data: - Operating pressure max.: 10 bar
- Max. differential pressure:
- DN 15 (1/2") = 1.4 bar
- DN 20 (3/4") = 0.7 bar
- DN 25 (1") = 0.6 bar
- For the integration of a hot water solar system on an instantaneous water heater or gas combi boiler
- If the hot water from the solar storage tank is warmer than 48°C, it is routed past the instantaneous water heater through the changeover valve and no energy is used for heating.
Technical data: - Max. operating temperature: 90°C