Control unit for fan unit EventAir/EvenTwinAir
XXX.XX
€/unit
|
XXX.XX
€/unit
Description • Controls with membrane keypad for switching the various EventAir and EvenTwinAir operating modes and output levels • 4 output levels off/15/20/30/40 m³/h • Summer mode (supply or extract air mode without heat recovery) • Winter mode (reverse mode with heat recovery) • Sleep timer function (device switches off at the touch of a button and goes back into operation after 2 hours of sleep time) • Filter change indicator (flashing LED after 3 months) • External input for combination with bathroom exhaust air unit (Fan units run with a supply air boost to avoid underpressure in the room) • Max. devices to be connected: - EventAir: up to 4 - EvenTwinAir: up to 2 • With integrated Power supply units • Input voltage: 230 V/5 0Hz • Output voltage: 12 V • Functional voltage range: 0-5V PWM • Protection class: IP 20 • Control unit dimensions (W x H x D): 80 x 80 x 49 mm • Installation in deep flush-mounted box possible Technical data
|