GIRA control unit 1-10V 4-way with manual actuation for KNX REG
XXX.XX
€/unit
Description • Division units: 4 • Control voltage: 1-10 V • Switching outputs: - Switching voltage: AC 250/400 V - Switching current 230 V AC1: 16 A - Switching current 230 V AC3: 10 A - Switching current 400 V AC1: 10 A - Switching current 400 V AC3: 6 A • The control unit switches and dims electrical loads that have a 1-10 V interface • Relay: - Number: 4 - Contact: 1 x NO contact each, floating, bistable • Control outputs: - Control current per output: max. 100 mA - Cable length: max. 500 m with 0.5 mm² - Fluorescent lamps: 16 AX • Lamp loads: - Incandescent lamps: 3680 W - HV halogen: 3680 W - Wound transformer: 2000 VA - Tronic transformer: 2500 W • Fluorescent lamps T5/T8: - Uncompensated: 3680 W - Parallel-compensated: 2500 W / 200 µF - Duo circuit: 3680 W / 200 µF • Compact fluorescent lamps: - Uncompensated: 3680 W - Parallel-compensated: 2500 W / 200 µF • Mercury vapour lamps: - Uncompensated: 3680 W - Parallel compensated: 3680 W / 200 µF • Ambient temperature: -5 to +45°C • Connections: - KNX: Connection and branch terminal - 1 - 10 V: Screw terminals - Load: Screw terminals • Connection cross-section: max. 4 mm² • 5 device configurations can be selected. This is used to assign the 4 individually controllable dimming channels to the switching outputs (e.g. 4 dimming channels are assigned to a Switching relay to control an RGBW light) • Relay outputs that are not assigned to a dimming channel can be used as freely acting switching actuator channels • Reactions on bus voltage failure and recovery and after an ETS programming operation can be set • Manual actuation of the outputs independently of the bus with mechanical switching position indicator • Delay for actively transmitting feedback signals after bus voltage recovery • Logical linking function configurable for each Ducts • Up to three central switching functions for common control of all Dimmers and switching channels • Switch-on times of the relay outputs can be recorded and evaluated by operating hours counters • Collective feedback of all switching states possible • Electronic ballasts generate very high current peaks. Therefore, use an inrush current limiter or a separate load contactor for larger loads • Connection and branch terminal included in the scope of delivery Dimming channels: • Four individually controllable dimming channels • Feedback of switching status and brightness value • Setting of the dimmable brightness range possible • Dimming behaviour and dimming characteristics can be parameterised • Soft switch-on and soft Off-switch function • Disable function or forced position function can be parameterised • Time functions (switch-on, switch-off delay, staircase lighting function). With the staircase lighting function, the reaction at the end of the switch-on time can be parameterised • Inclusion of a dimming channel in up to 10 scenes possible • Burn-in function enables the commissioning of new Fluorescent lamps as prescribed by the light source manufacturer Switch actuator operation (optional): • Independent switching of Switches A2 to A4 • Normally open or normally closed operation • Feedback of the switching status • Disabling function or forced position function can be parameterised • Time functions (switch-on, switch-off delay, staircase lighting function with pre-warning function) • Inclusion in light scenes possible. Up to 10 internal scenes can be parameterised for each switching output • Cyclical monitoring of the incoming switching telegram can be configured Technical data
|
Products |