GIRA control unit 1-10V 4-way with manual actuation for KNX REG
XXX.XX
€/unit
Description • Division units: 4 • Control voltage: 1-10 V • Switch outputs: - Switching voltage: AC 250/400 V - Switching current 230 V AC1: 16 A - Switching current 230 V AC3: 10 A - Switching current 400 V AC1: 10 A - Switching current 400 V AC3: 6 A • The controller unit switches and dims electrical devices that have a 1-10 V interface • Relays: - Number: 4 • Contact: 1 x NO contact each, floating, flip-flop • Control outputs: - Control current per output: max. 100 mA - Cable length: max. 500 m with 0.5 mm² - Fluorescent lamps: 16 AX • Lamp loads: - Incandescent lamps: 3680 W - HV halogen: 3680 W - Coiled transformer: 2000 VA - Tronic transformer: 2500 W • Fluorescent lamps T5/T8: - Uncompensated: 3680 W - Parallel-compensated: 2500 W / 200 µF - Duo circuit: 3680 W / 200 µF • Compact fluorescent lamps: - Uncompensated: 3680 W - Parallel-compensated: 2500 W / 200 µF • Mercury vapour lamps: - Uncompensated: 3680 W - Parallel-compensated: 3680 W / 200 µF • Ambient temperature: -5 to +45°C • Connections: - KNX: connection and junction terminal - 1 – 10 V: screw terminals - Load: screw terminals • Connection cross-section: max. 4 mm² • 5 device configurations can be selected. This leads to the assignment of 4 individually-controllable dimming channels to the switching outputs (e.g. 4 dimming channels are assigned to one switching relay to control an RGBW light) • Relay outputs that are not associated with a dimming channel can be used as freely-acting switching actuator channel • Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process • Manual actuation of the outputs independently of the bus with mechanical switching position indication • Delay for actively transmitted feedback messages following bus voltage recovery • Logical linking function configurable per channel • Up to three central switching functions for the joint control of all dimming and switching channels • Switch-on times of the relay outputs can be recorded and evaluated by the operating hours counter • Group feedback of all switching conditions possible • Electronic ballasts generate very high current spikes. Use a switch-on current limiter or a separate load contact for greater loads. • Connection and junction terminal supplied Dimming channels: • Four individually controllable dimming channels • Feedback on switching condition and brightness value • Dimmable brightness range can be set • Dimming behaviour and dimming characteristics can be parameterised • Soft switch-on and soft switch-off function • Block function or forced setting function can be parameterised • Time functions (switch-on, switch off delay, staircase light function). With the staircase light function, the reaction at the end of the switch-on time can be configured • Inclusion of a dimming channel in up to 10 scenes is possible • The burning-in function allows for the start-up of new fluorescent lamps prescribed by lighting manufacturers Switching actuator operation (optional): • Independent switching of switch outputs A2 to A4 • NO and NC contact operation • Feedback of the switching state • Block function or forced setting function can be parameterised • Time functions (switch-on, switch-off delay, staircase light function - also with advance warning function) • Can be integrated into light scenes Up to 10 internal scenes per switching output are programmable • Cyclical monitoring of incoming switching telegram is configurable Technical data
|
Products |