Jung switch/blind actuator Secure KNX REG
XXX.XX
€/unit
Description • Nominal voltage KNX: DC 21-32 V SELV - Switching voltage: AC 250 V ~ - Switching current AC1: 16 A • Project design and commissioning with ETS5 or a more recent version • Switching of electrical loads with floating contacts and electrically operated blinds, roller shutters, awnings and similar • Ambient temperature: -5 to +45°C • Fluorescent lamps: 16 AX • Current carrying capacity: - Adjacent outputs: Σ 20 A • Loads per output: - Ohmic load: 3000 W - Capacitive load: 16 A / 140 µF - Motors: 1380 VA - Switching current 200 µs: max. 800 A - Switching current 20 ms: max. 165 A • Lamp loads 230 V: - Incandescent lamps: 2300 W - HV halogen lamps: 2300 W - HV-LED lamps: max. 400 W • LV halogen lamps: - With electronic transformers: 1500 W - With inductive transformers: 1200 VA • Fluorescent lamps T5/T8: - Uncompensated: 1000 W - Parallel-compensated: 1160 W / 140 µF - Duo circuit: 2300 W / 140 µF • Compact fluorescent lamps: - Uncompensated: 1000 W - Parallel-compensated: 1160 W / 140 µF • Mercury vapour lamps: - Uncompensated: 1000 W - Parallel-compensated: 1160 W / 140 µF • Connections, power supply and load: - Connection type: screw terminals - Single wire: 1 x 0.5 ... 4 mm² - Fine wire without ferrule: 1 x 0.5 ... 4 mm² - Fine wire with ferrule: 1 x 0.5 ... 2.5 mm² - KNX: KNX connection terminal • Outputs can be controlled manually, building site operation • Feedback in manual and bus mode • Blocking of individual outputs by hand or bus • Central functions • Cyclical monitoring • KNX Data Secure compatible from ETS 5.7.3 • Can be updated with ETS Service app • Switching mode properties - NO and NC contact operation - Feedback function - Linking and forced guidance functions - Central switching function with group feedback - Time functions: Switch-on and switch-off delay, staircase light with advance warning function - Scene function - Operating hours counters • Blind mode properties - Suitable for AC motors 230 V - Operating modes “Slat blind”, “Roller shutter/awning”, “Ventilation flap/skylight” - Curtain position and slat position can be controlled directly - Feedback on movement status, curtain position and slat position - Cyclical feedback in movement mode - Forced position with higher level controller - Safety function: rain alarm, frost alarm, 3 independent wind alarms - Sun protection function with automatic heating-cooling - Apply loads to adjacent outputs only up to a total output current of 20 A Technical data
|
Products |